RPA 'Ecomed',
129090, Russia, Moscow, POB no. 87,
tel. 963-11-22, tel./fax 963-05-97,
email: ecomednpo@mtu-net.ru,
site: www.npoecomed.com


STUDY TITLE

MUCOUS MEMBRANE IRRITATION STUDY IN THE HAMSTER CHEEK

(Collar Method, 14 Day Exposure)

TEST ARTICLE

AES Capsule. Multi Gate Korea Co., Ltd.

IDENTIFICATION NO

P-6551-KL

Lab No.

96C 21827 01


SUMMARY

A cheek pouch mucosal irritation study was conducted in the hamster. The test article, AES Capsule, Multi Gate Korea Co., Ltd, Identification No. P-6551-KL, was placed into the right cheek pouch of ten hamsters; the left cheek pouch of all ten animals was implanted with polymethylmethacrylate (PMMA) discs which served as the comparative control. Materials were held in place with fitted collars. After 2 weeks of exposure, the hamsters were euthanatized and their pouch mucosa recovered in toto for microscopic tissue evaluation.

Cheek pouches were grossly normal in appearance when observed for irritation at day 14. Microscopic evaluation of cheek pouch mucosa was within normal histomorphological limits.

Under the conditions of this study, the test article would not be considered irritating to the hamster cheek pouch. As anticipated, the PMMA reference control article was not an irritant.

Study and Supervisory
Personnel:
Chris Weeks, B.S.
Daphne Berry, B.S., LAT
Lewis Akers, B.S., LAT
Jane Herriges, B.A., ALAT
David Vergil




 
Approved by
12-27-96    
 Daphne Berry, B.S., LAT
Section Manager, Testing Services
Toxicology
Report Date



World Leader in Testing Services
for the Medical Device Industry
9 Morgan
Irvine, CA 92618
TEL.: (714) 951-3110
FAX: (714) 951-3280

Authorizaiton for duplication of this report, except in whole, is reserved pending NAmSA's written approval